[Documentation] [TitleIndex] [WordIndex

Experimental

EXPERIMENTAL: This status indicates that this software is experimental code at best. There are known issues and missing functionality. The APIs are completely unstable and likely to change. Use in production systems is not recommended. All code starts at this level. For more information see the ROS-Industrial software status page.

Overview

The rgbd_depth_correction package provides a tool for calculating and correcting the depth error (distortion and bias) of a RGBD camera. This is done by placing a calibration target on a flat surface, then comparing the sensor depth data to the position found using the calibration target.

This method requires two things:

The calibration results are then used by the depth correction nodelet which runs in the camera nodelet manager and publishes a corrected point cloud.

RGBD point cloud prior to correction RGBD point cloud after correction

Motivation

As was found by Daniel Herrera C., Juho Kannala, and Janne Heikkila, (http://www.cse.oulu.fi/~dherrera/papers/2012-KinectJournal.pdf), RGBD cameras have not only depth error that is radial, but is depth dependent. In order to correct for this depth error, a series of images must be taken of a calibration target on a flat surface. This package provides a method for calibrating and correction this depth error.

Tutorials


2024-12-07 15:03